DTC Advanced Diagnostics: B2800-49
DTC B2800-49: Internal Failure of the SRS Unit
NOTE
Always check "How to troubleshoot the SRS system" and proceed along each "DTC Troubleshooting" procedure.
Make sure the 12 volt battery is fully charged. If not, the results of tests may not be accurate.
The SRS indicator will turn on when the 12 volt battery voltage becomes below 10 volts.
The possible causes shown may not be a complete list of all potential problems, and it is possible that there may be other causes.

Confirmation Procedure
Basic Condition:
12 volt battery voltage 10 - 16 V

Operating Condition:
1.
Turn the vehicle to the ON mode, and wait 6 seconds.
Duration
About 6 seconds
DTC Type
1 drive cycle
SRS indicator on
Fail Safe Action
None
Possible Cause
SRS unit internal failure