Automatic Lighting Control Unit-Sensor Connector for Inputs and Outputs
Automatic Lighting Control Unit-Sensor 5P Connector (female terminals)


Terminal number
Terminal name
Description
Signal
1
B-CAN_H
Communication line
???
2
B-CAN_L
Communication line
???
3
GND
Automatic lighting control unit-sensor ground
Less than 0.2 V at all times
4
?B BACK UP
?B power source
About battery voltage at all times
5
H/L ON SW
Outputs H/L ON SW signal
With combination light switch is in ON position: less than 0.2 V
With combination light switch is in AUTO position and the conditions for the headlight to be ON: less than 0.2 V
If none of above conditions are met: about battery voltage